Zitierlink: http://dx.doi.org/10.25819/ubsi/9920
Dateien zu dieser Ressource:
Datei Beschreibung GrößeFormat
Zebrafish_larvae_show_negative_phototaxis.pdf1.1 MBAdobe PDFMiniaturbild
Öffnen/Anzeigen
Dokumentart: Article
Titel: Zebrafish larvae show negative phototaxis to near-infrared light
AutorInn(en): Hartmann, Sarah 
Kunze, Jan 
Vogt, Roland 
Rauschert, Anna 
Kuhnert, Klaus-Dieter 
Wanzenböck, Josef 
Lamatsch, Dunja K 
Witte, Klaudia 
Institut: Institut für Biologie 
Schlagwörter: Zebrafish, Phototaxis
DDC-Sachgruppe: 590 Tiere (Zoologie)
GHBS-Notation: VOA
VQS
VSC
Erscheinungsjahr: 2018
Publikationsjahr: 2021
Auch erschienen: PLoS ONE ; 13 (11), e0207264. - https://doi.org/10.1371/journal.pone.0207264
Zusammenfassung: 
Zebrafish larvae (Danio rerio) are among the most used model species to test biological effects of different substances in biomedical research, neuroscience and ecotoxicology. Most tests are based on changes in swimming activity of zebrafish larvae by using commercially available high-throughput screening systems. These systems record and analyse behaviour patterns using visible (VIS) and near-infrared (NIR) light sources, to simulate day (VIS) and night (NIR) phases, which allow continuous recording of the behaviour using a NIR sensitive camera. So far, however, the sensitivity of zebrafish larvae to NIR has never been tested experimentally, although being a critical piece of information for interpreting their behaviour under experimental conditions. Here, we investigated the swimming activity of 96 hpf (hours post fertilization) and 120 hpf zebrafish larvae under light sources of NIR at 860 nm and at 960 nm wavelength and under VIS light. A thermal source was simultaneously presented opposite to one of the light sources as control. We found that zebrafish larvae of both larval stages showed a clear negative phototactic response towards 860 nm NIR light and to VIS light, but not to 960 nm NIR light. Our results demonstrated that zebrafish larvae are able to perceive NIR at 860 nm, which is almost identical to the most commonly used light source in commercial screening systems (NIR at 850 nm) to create a dark environment. These tests, however, are not performed in the dark from the zebrafish´s point of view. We recommend testing sensitivity of the used test organism before assuming no interaction with the applied light source of commonly used biosensor test systems. Previous studies on biological effects of substances to zebrafish larvae should be interpreted with caution.
Beschreibung: 
Finanziert aus dem DFG-geförderten Open-Access-Publikationsfonds der Universität Siegen für Zeitschriftenartikel
DOI: http://dx.doi.org/10.25819/ubsi/9920
URN: urn:nbn:de:hbz:467-19090
URI: https://dspace.ub.uni-siegen.de/handle/ubsi/1909
Enthalten in den Sammlungen:Geförderte Open-Access-Publikationen

Diese Ressource ist urheberrechtlich geschützt.

Zur Langanzeige

Seitenansichten

400
checked on 01.12.2024

Download(s)

57
checked on 01.12.2024

Google ScholarTM

Prüfe

Prüfe


Alle Ressourcen in diesem Repository sind urheberrechtlich geschützt, soweit nicht anderweitig angezeigt.